Air conditioning sheet metal components: Introduction and function of buffer water tank in air conditioning system


Air conditioning sheet metal components: What is a buffer water tank?
Connecting buffer water tanks in series in the central air conditioning system can increase the water capacity of small systems, store cooling or heat, and effectively solve problems such as load fluctuations and frequent host startup caused by small systems, thus achieving the goal of extending equipment service life and saving energy.
Air conditioning sheet metal components: unique function of buffer water tank
1. Forced automatic exhaust function in the system
As long as the function of reducing the number of starts and stops of the host is reduced, a buffer water tank can be installed in the host's water outlet pipeline or indoor water return pipeline.
2. Protection of the power component water pump in the water system
The bottom outlet of the buffer water tank is connected to the suction port of the water pump, and the water from the suction port is airless (air cannot come down from the upper part of the water tank), which greatly reduces the cavitation phenomenon of the water pump impeller. The water sucked in is pure water, and the water circulating by the water pump will naturally push the gas in the system to the outlet of the system, and then enter the upper inlet of the buffer water tank. The gas brought by the system outlet will be forcibly discharged by the exhaust valve at the top of the water tank, which becomes a virtuous cycle. In a non buffered water tank system, when the water pump sucks in water containing gas, the impeller will break the gas into the system, resulting in the presence of gas everywhere in the system, making it more difficult to discharge. The flow switch of the water pump often alarms and keeps starting and stopping, greatly increasing the difficulty of debugging.
3. Avoid high-voltage protection of the host.
The water entering the motherboard for exchange is pure (gas free) water, which can better exchange energy and increase heat exchange efficiency.
4. Easier debugging and faster results.
When the system's water supply reaches half, debugging can begin. The water flowing into the host and water pump is pure and airless, and the heat will be quickly transmitted to the end, greatly reducing debugging time. In the early days, the author engaged in air conditioning construction, debugging a villa, and couldn't finish it in three or four hours. Because there is too much gas in the water, the flow switch often gives an alarm, and the heat exchange of the host is insufficient, it will be protected by high pressure. But the effect after gas blockage is not significant. Both of these greatly extend debugging time. In a computer room system with a buffer water tank, it usually takes one to two hours to complete debugging.
5. The system discharge is more thorough, preventing system blockage, and making discharge more convenient.
The impurities in the pipeline are constantly circulating because after passing through a vertical large capacity water tank, many impurities will accumulate at the bottom of the buffer water tank. After passing through a Y-shaped filter, the water quality will be much better, reducing the number of times the filter is cleaned. The drainage outlet of the buffer water tank is set at the bottom of the water tank and equipped with a manual drainage valve, making cleaning more convenient.
6. Winter heating makes the system operate more stably.
When using small air-cooled heat pumps in severe winter, the impact of defrosting time on indoor temperature is a headache. If the host is equipped with auxiliary electric heating and defrosting, the COP value of the host will be greatly reduced.
The above is an introduction to "Air conditioning sheet metal components: What is a buffer water tank?", and any other questions are welcome to consult us.

News


Analysis of the Current Situation of Automotive Parts Procurement Management

According to data, about 70% of the total cost of automobiles is a part of automobile parts procurement. When the procurement cost decreases by 1%, profits increase by 5-10%, and when sales increase by 1%, profits only increase by 1%. It is obvious that reducing procurement costs can easily increase profits and enhance competitive advantages. So, let's take a look at the automotive parts procurement system and supplier management analysis together!


What are the characteristics of air conditioning sheet metal components?

Sheet metal is a product processed by sheet metal technology, and we cannot live without sheet metal everywhere. Sheet metal parts are made through filament power winding, laser cutting, heavy processing, metal bonding, metal stretching, plasma cutting, precision welding, rolling forming, sheet metal bending forming, die forging, and water jet cutting.


Air conditioning sheet metal components: Introduction and function of buffer water tank in air conditioning system

Connecting buffer water tanks in series in the central air conditioning system can increase the water capacity of small systems, store cooling or heat, and effectively solve problems such as load fluctuations and frequent host startup caused by small systems, thus achieving the goal of extending equipment service life and saving energy.


What precautions should be taken when customizing a sheet metal processing cabinet for automotive charging cabinets?

Car charging cabinet sheet metal manufacturers: What are the precautions for customizing sheet metal processing cabinets?


Reasons and Solutions for Edge Burning of Popular Laser Cutting Machines Used by Automobile Charging Cabinet Sheet Metal Manufacturers

Reasons and Solutions for Edge Burning of Popular Laser Cutting Machines Used by Automobile Charging Cabinet Sheet Metal Manufacturers Reasons and solutions for edge burning in laser cutting machines Today, the sheet metal manufacturer of car charging cabinets will share with you the reasons and solutions for the edge burning of popular laser cutting machines. I hope the following content can help everyone. Car charging cabinet sheet metal manufacturer: analysis of the reasons for edge burning of metal laser cutting machines The reason for edge burning and slag sticking in laser cutting of sheet metal parts: When laser cutting sheet metal parts, a large amount of heat is generated. Generally, the heat generated by cutting will diffuse along the slit into the processed metal plate, obtaining sufficient cooling. When metal laser cutting machines process small holes, the outside of the hole can be fully cooled, but the heat diffusion space inside a single hole is small, and the heat energy is too concentrated, leading to phenomena such as overburning and slag hanging. In addition, in thick plate cutting, the molten metal and heat accumulated on the material surface during perforation can cause auxiliary airflow disorder and excessive heat input, leading to overburning. Car charging cabinet sheet metal manufacturers: How to solve the problem of burning edges and slag hanging Solution to overburning in laser cutting of carbon steel holes: In carbon steel cutting with oxygen as the auxiliary gas, the key to solving the problem lies in how to prevent the generation of oxidation reaction heat. When piercing, auxiliary oxygen cutting is used, and after a delay, auxiliary air or nitrogen cutting is used. This method can process holes in 1/6 thick plates. Pulse cutting conditions with low frequency peak output power can reduce heat output and help optimize cutting conditions. Setting the conditions as a single pulse laser beam, high energy intensity, and low frequency peak output can effectively reduce the accumulation of molten metal on the material surface during the perforation process, effectively stopping heat output. Solution for laser cutting of aluminum alloy and stainless steel: In the processing of such materials, nitrogen gas is used as the auxiliary gas, and there will be no burning phenomenon during cutting. However, due to the high temperature of the material inside the small hole, the phenomenon of internal slag hanging will be more frequent. An effective solution is to increase the pressure of the auxiliary gas and set the conditions to high peak output and low-frequency pulse conditions. When using air as the auxiliary gas, just like when using nitrogen, there will be no overburning, but bottom slagging is easy to occur. Therefore, it is necessary to set the conditions to high auxiliary gas pressure, high peak output, and low-frequency pulse. The above is the reason and solution for laser cutting machine edge burning explained by the sheet metal manufacturer of the car charging cabinet. Do you all understand? If you want to learn more about relevant knowledge, please feel free to contact our automotive charging cabinet sheet metal manufacturer. We will wholeheartedly serve you and hope that the knowledge explained above can help you. Thank you for your patience in watching and wish you a happy life.

Related News